Len Gordon Micro Topside Y2K | 1 Button 3 Light | 931213-000   SD6600-051 PANEL SUNTUB  

Genuine Len Gordon Topside Controls
 
SD6600-051 PANEL SUNTUB
$280.61
 
ERROR CODES FOR TOPSIDE CONTROLS

Brett Digital Error Codes
OH = Temp exceeds 118 degrees
Fr = Freeze condition – temp below 40 degrees
FL = Pressure switch failure
EO = Shorted temp sensor
E1 = Open temp sensor
E2 = Shorted hi-limit sensor
E3 = Open hi-limit sensor
E4 = Shorted fl ow switch
E7 = Improper electrical connection
FC = Filter cycle

Sundance Error Codes
ILOC = Interlock failure
OH = Sensor indicates water temp above acceptable limits
FLO = Pressure Switch malfunction
Hold = Panel buttons pressed too many times to quickly
HOT-– Air blower on
ICE = Freeze condition
PnL = Communication error between circuit board & panel
Sn1 = Hi-limit sensor malfunction
Sn3 = Temp sensor malfunction
“-----” = Watch dog – Water temp above acceptable limits (above 118°). Potential damage to spa equipment.
Possible sensor, transformer, topside or circuit board failure

Spa Builders LX 10/15 Error codes
Sn1 / 01 Nonfunctional /open high temperature sensor. Heater deactivated
Sn2 / 02 Nonfunctional /open temperature sensor. Heater deactivated
FL1 / 03 Pressure switch not closed when pump is running and heater is trying to heat, Heater is also
deactivated
FL2 / 04 Pressure switch is closed when pump is off
COL / 05 Cool Condition Water Temp has dropped 20° below set temperature low speed pump & heater will
activate to bring temperature to within 15° of preset; only works in economy mode
ICE = Freeze condition. Water temp has reached 55°; pump & heater are activated
OH = Water temp above acceptable limits (above 110°)
“---” = Watchdog Water temp above acceptable limits (above 118°). Potential damage to spa equipment.
Possible sensor, transformer, topside or circuit board failure

Gecko Error Codes (old style)
FLO = Pressure switch open
FLC = Pressure switch closed
Prr = temp sensor failure
Prh = Hi-limit sensor failure
FrE = Possible freeze condition

Gecko Error Codes (new style) / Hydro-Quip Error Codes
32° = Temp sensor not detected
112° Flashing = Water too hot; let cool down & system will reset itself @ 109°
3 Flashing dots on display = water fl ow problem check for closed valves, dirty fi lters, water level, pump/
wet end operation / defective pressure switch.
Flashing dots & light lit on circuit board = Hi-limit trip. Reset power to clear
Temp reads correct water temp = Good; if incorrect replace sensor
Inverted Display = Press Filter key for 5 seconds (certain models only)
Pump starts by itself for 1 minute on several occasions & Filter indicator fl ashing = Smart Winter Mode not
an error but a feature (Freeze protection)
Filter cycle has stopped & “Filter” indicator is fl ashing not an error but a feature; either the fi lter cycle is in
a 40 minute time-out to avoid ozonator activation while spa is being used or the system has cancelled a
fi lter cycle after 3 hours because water temp exceeds set point by more than 2°
“Heater” indicator fl ashes when pump is on high speed. Not an error but a feature. The system is turning
off the heater when pump is on high speed to limit amperage draw (jumper 1 set to “LC” mode)
Temperature displays water temp “C°” or “F°”. Simply hold light button for 5 seconds to toggle.
Technical note: After making any changes to any P.C.B or control system; RESET the Breaker

Lennovator Error Codes
“SP” = SPA MODE ; not an error
“PO” = POOL MODE; not an error
“NC” = No Communication With Master Control Unit
“- - “ = Data Being Sent To Master Control Unit
“OP” = Temperature Sensor Failure-open
“SH” = Temperature Sensor Failure-shorted
“OH” = Warning, Water Temperature Over 120°f
“IP” = Insuffi cient Power
“FP” = Freeze Point
Temperature: Set Point & Actual Water Temp
Temperature Flashing On & Off - Warning - Water temperature high (109°-120°F)

 

 Contact Us
Product Manuals
Coupons
 Popular Products
 Len Gordon Micro Topside Y2K | 1 Button 3 Light | 931213-000 Len Gordon Micro Topside Y2K | 1 Button 3 Light | 931213-000
$39.33
 SD6600-051 PANEL SUNTUB SD6600-051 PANEL SUNTUB
$280.61
Pool Supply Unlimited specializes in pool and spa supplies at discount prices. With over 20 years in the swimming pool industry, we utilize our knowledge to help your pool be its best!

All products sold are Brand New. No used or refurbished items.

Order Pick-Up Available in Ontario, California for local customers by appointment only. Please call (888) 836-6025 to schedule an appointment.
  Reseller Ratings Elite
v. 7.23
Order Information

Contact Us
Hours of Operation
International Orders
My Account

Login
Forgot Password
Current Order
Bookmark Us
Company Info

About Us
Testimonials
Reseller Ratings
Better Business Bureau
FAQ
Terms & Conditions
Privacy
Resources

Product Manuals
Coupons
Rebates
Site Map
Links
Articles
Follow Us

YouTube You Tube
Facebook Facebook
 
Twitter Twitter
Google Plus Google +
 
 Copyright ©2011 Pool Supply Unlimited. All Rights Reserved. Website by Radiant