The pH electrodes utilize a GP bulb glass, featuring fast response over the range of 0-12 pH. The ORP electrodes include a solid platinum band fused to its bulb glass for optimum reading. The electrodes can be used continuously 0-60 C, and intermittently up to 100 C. Maximum pressure is 60 PSI.
Chemtrol pH Sensor NSF 50 designed for rugged pH/ORP service applications; the bodies of these electrodes are made from impact resistant epoxy tubing. The electrodes are designed with Ag/AgCl gel-filled/ sealed reference and dual ceramic pin wicks to offer excellent results with minimum maintenance. They also include low noise coaxial cable with dual shields.
Features:
- The sensors are made from impact resistant epoxy tubing, ceramic and glass
- The dual ceramic pin wicks design help resist clogging and perform longer
- ORP Range: 0-999 mV
- Temp Range: 0-60 C
- Max Pressure/Temp 60 psig at 60 C
- Reference Ag/AgCl
- Wetted Materials Epoxy, Ceramic and Glass
- Standard cable length 3 meter